Member Center
CE for Building
Standard for CE
Other Standard
Contact Us
TeL:(+86) 025-8658 3475
Fax:(+86) 025-8658 3457
E-mail:info@hksmartps.com
Website:http://www.hksmartps.cn
NF X 70-100: Toxicity
1. Standard-- NF X 70-100
NF X 70-100: Fire behaviour tests –Analysis of pyrolysis and combustion gases-Pipe still method.
The test is conducted within a tube furnace where the temperature is set at either 400°C, 600°C or 800°C (commonly600°C is used for most materials or 800°C in the case of some electrical products). 40 minutes throughout the test. By (CO, CO2, HCI, HBr, HCN, HF, SO2) analysis of these gases toxicity index.
2. NF X 70-100 for assessing F classification (smoke density and toxicity)
NF X 10-702 for assessing F classification (smoke density and toxicity)
NF F 16-101:1988 referenced in this standard (NF X 70-100) and the NF X 10-702 for the F-level smoke toxicity testing
According to NF X 70-100 and NF X 10-702 results of two tests to assess the toxicity of F-class level of F0-F5 smoke six levels (F0, F1, F2, F3, F4, F5)
Class |
Value of S.I. |
F0 |
≤5 |
F1 |
≤20 |
F2 |
≤40 |
F3 |
≤80 |
F4 |
≤120 |
F5 |
>120 |
NF X 10-702: Fire test methods-Smoke emission-Test of measurement of specific optical density of smoke by the combustion or the pyrolysis of solid materials.
NF X 70-100: Fire behaviour tests –Analysis of pyrolysis and combustion gases-Pipe still method.
NF F 16-101: Railway rolling stock fire behaviour choice of materials
NF F 16-102: Railway rolling stock fire behaviour choice of materials-Electrical Equipment
Tel:(+86)400-603-6575